Preface and general information – Lenze 8200 Frequency inverters User Manual
Page 24

Preface and general information
8200SHB0199
1-8
Components of the CE-typical drive system
System component
Specification
Controller
820X/821X/822X/824X controllers
For type designation see inner cover page
RFI filter
For data and data assignment, see chapter ”Accessories”
Mains choke
For data and data assignment, see chapter ”Accessories”
Mains filters
For data and data assignment, see chapter ”Accessories”
Motor cable
Screened power cable with tinned E-CU braid with a minimum of 85 % optical
coverage
Mains cable between RFI filter
and controller
As from cable length 300 mm:
Screened power cable with tinned E-CU braid with a minimum of 85 % optical
coverage
Control cables
Screened signal cable type LIYCY
Motor
Standard three-phase AC asynchronous motor
Lenze type DXRA or similar
Accessories
For rated accessories, see inner cover page.
-
Controller, RFI filter and mains choke are mounted on one assembly board.
-
The system components are functionally wired according to chapter 4,
”Electrical installation”.
Application as directed/Scope of application
-
The 820X/821X/822X/824X controllers are intended for the use in control
cabinets.
-
The 820X/821X/822X/824X controllers are directed as components for the
control of variable-speed drives with three-phase AC motors to be
assembled together with other components to form a drive system.
The drive systems are intended for installation into a machine or for the
construction together with other components to form a machine or a plant.
-
Drive systems with the 820X/821X/822X/824X controllers, which are
installed according to the guidelines of CE-typical drive systems,
correspond to the EC EMC Directive and the standards mentioned below.
-
The CE-typical drive systems are suitable for the operation on public and
non-public mains.
-
The CE-typical drive systems are provided for the operation in industrial
premises as well as in residential and commercial areas.
-
Because of the earth-potential reference of the RFI filters, the described
CE-typical drive systems are not suitable for the connection to IT-mains
(mains without earth-reference potential).
-
The controllers are not domestic appliances, but they are intended as a part
of drive systems for commercial use.
Show/Hide Bookmarks