Installing Hardware

Installing a second HDD cage

61

12 Rebuild the disk array (if the RAID controller is installed). For details, refer

to the appropriate RAID manual.

NOTE: The disk array cannot be rebuilt if Power Console (for Windows NT)
or MegaRAID

®

Manager (for NetWare

®

) is not installed.

Installing a second HDD cage

The Magnia7010 server comes with a HDD cage capable of holding up to six
disk devices. A second HDD cage may be installed to provide slots for an
additional six HDD devices.

NOTE: This procedure only installs the cage. You also need to install disk
drive units.

1 If the server is running, shut it down, set the AC switch on the back of the

server to OFF, and unplug the power cable.

2 Remove the server cover. For more information, see “Removing and

replacing the server panels” on page 19.

3 Remove the six screws securing the front frame and remove the frame.

4 Remove the four screws securing the dust cover plate and remove it.

Front frame