Operating with extremely high loads, Auto rebuild with a hot spare – Toshiba Magnia 7010 User Manual

Page 131

background image

System Configuration Setup

Disk array setup (RAID)

115

Operating with extremely high loads

The following may occur when the server operates with extremely high loads.

™

The following message may appear in the Application Log of the Windows
NT Event Viewer:

Event ID: 9

Source: mraid35x

(Explanation) Device SCSI Port did not reply within the timeout.

™

When attempting to start or execute Power Console, proper execution may
halt and the following window may appear:

No MegaRAID Adapter card found!

[OK]

If this occurs, press

Enter

and restart Power Console when the load decreases.

Auto rebuild with a Hot Spare

After finishing an auto rebuild in a RAID configuration with a Hot Spare, the
fault LED at the failed drive automatically turns off, leaving no indication that a
failure occurred. To ensure that an audible warning will be heard, even after the
LED has automatically turned off, set the Alarm Control option to Enabled.