Troubleshooting Guide

Toshiba Technical Support

131

command during the SCSI ROM boot. Please change any SCSI BIOS defaults
to properly start all hard disk drives during its ROM load. Most notably, this
setting is necessary on all Adaptec controllers.

Please refer to the user’s manual of the installed RAID controller for additional
details on configuring the SCSI BIOS.

Status LED indications

If you observe any of these indications, call your authorized Magnia service
provider as soon as possible:

NOTE: If the POWER indicator glows amber, this does not indicate
anything wrong. It shows that AC power input is normal and that there is no
DC output.

Forced shutdown

If you perform a forced shutdown and your system will not restart when you
press the power on/off switch, reset the AC switch on the back of the server,
then turn on the power again.

Toshiba Technical Support

If you have problems, or if you need assistance, call Toshiba Technical Support.

LED

State

Possible Cause

Power

Off

AC power not supplied

Flashing amber

Invalid number of power supplies

Disk

Amber

Faulty HDD

Fault

Flashing green and
amber

Fan/power supply failure