Power requirements, Rack model – Toshiba Magnia 7010 User Manual
Page 20

Getting Started
Power requirements
4
Minimum safe distances
Rack model
NOTE: Installing a rack model of the Magnia7010 requires special
techniques and knowledge. Toshiba recommends that you call an
authorized Magnia service provider.
In addition to the pedestal environmental considerations, if you are installing a
rack model, keep in mind these additional considerations:
Install the server or rack on a level surface.
The equipment rack must provide sufficient airflow to the front of the server
to maintain proper cooling. Keep the vent on the front and rear sides clear
about 24 inches (60 cm).
Power requirements
The server is supplied with an AC power cable with a rating of up to 15
amperes. When deciding how to connect the equipment to the power outlet,
consider the possible effect of overloading circuits.
The overall rating of a server configured with four power supplies is 800 watts.
To supply reliable grounding of the server, you must use the supplied power
cable.
NOTE: Toshiba recommends that you use a UPS for both pedestal and
rack models.
8 inches (20 cm) or more
2 inches (5 cm) or more
14 inches (35 cm) or more
2 inches (5 cm) or more