Smc board sensor setup – Toshiba Magnia 7010 User Manual
Page 124
System Configuration Setup
Using the Sensor Data and LCD Setup tool
108
Procedure After Removing a Redundant Power Supply and Redundant
FAN
The SMC board monitors any removal of a power supply and fan. If a
redundant power supply or redundant fan is removed, it will be detected and a
fault lamp will start blinking. To stop the fault lamp’s blinking, you must use
the Sensor Data & LCD Setup Tool to deactivate the redundant power supply
sensor or fan sensor on the SMC board. (It is re-activated automatically if an
additional power supply is installed.) Follow the procedure below:
SMC board sensor setup
1 Insert the Sensor Data & LCD Setup Tool floppy disk into the floppy disk
drive.
2 Turn on the server.
3 The following menu choices will appear:
Choose option “1. Setup SMC Board Sensor Data”
4 The program will show the current number of power supplies and fan mod-
ule.
5 Enter the new number of power supplies. The program will respond with
“OK.” To exit the program, press the
1. Setup SMC Board Sensor Data
2. Setup LCD Display Message
3. Setup Expansion HDD Chassis Sensor Data
TOSHIBA SMC Configuration Program VerX.XX
*** Setup Redundant ***
PS Unit Count: 0X
FAN Unit Count: 0X
*** Redundant Setting ***
SET PS Unit Count ([1] - [4] or [Esc]) >> X OK!
SET FAN Unit Count ([1] - [2] or [Esc]) >> X OK!
*** Setup Redundant END ***
HIT ANY KEY