Toshiba Magnia 7010 User Manual
Page 29
Getting Started
Front with doors open
13
CAUTION: If a failure occurs, contact your authorized Magnia service
provider.
Lamp indicators for a faulty power supply or cooling fan
If a power supply or cooling fan fails, the Fault indicator flashes. Before
contacting your authorized Magnia service provider, check for the faulty part.
Look at the LCD and check the location of the malfunction. Check the “LCD
Display” on page 9.
CAUTION: If two or more power supplies or cooling fans fail, immediately
shut down the system and switch off power. If the system is kept in
operation, it could result in destruction and loss of important programs and
data.
NOTE: The lamp indicators only show a fault of the power supply or fans.
The HDD cage has separate fault indicators for each of the hard disk drive
units.
Additional power supplies may be installed to provide system redundancy. If a
power supply in a redundant configuration fails, the system can continue to run
Fault
Off
DC OFF or normal operation
(AC OFF or all power supplies and fans
are OK)
Flashing Green
One of the redundant FAN/Power
supply has failed.
(System operation can resume.)
Flashing Amber
The non-redundant FAN/Power supply
has failed.
Or, the redundant FAN/Power supply
pair has failed.
(The system must be stopped
immediately.)
Type of Lamp
State
Meaning