B. Parametrising as per FHPP−FPC
B−81
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Position control parameter set
PNU
1024
18d...21d
int32
rw
Description
Caution: Risk of injury to people and damage to property.
The factory settings for the controller parameters should only be
modified in exceptional cases. Unfavourable settings can lead to
uncontrollable behaviour of the entire system.
·
Only change the controller parameters with the aid of FCT.
·
Follow the instructions in FCT for the controller parameters.
Position controller:
closed loop
1024
18
d
(CI: 12h)
closed loop
natural frequency Position controller: circuit frequency. Value range: 1...1000
Position controller:
damping
1024
19
d
(CI:13h)
damping
Position controller: damping. Value range: 100...5000
Current controller:
gain
1024
20
d
(CI:14h)
gain
Current controller: gain. Value range: 100...10000
Current controller:
integrating time
1024
21
d
(CI:15h)
integrating time
constant Current controller: I−share. Value range: 1...15000
CI / DS402
60FBh
12h...15h
int32
rw
Motor data
PNU
1025
1, 3
uint32
r
Description
Drive data
Serial number 1025
1
Serial number of the motor
I
2
t factor 1025
3
I
2
t factor. See PNU 1027.
CI / DS402
6410h
01h, 03h
uint32