Homing (requires status 1.4 or 1.5), Commissioning 5−54, Step/description control bytes status bytes – Festo Контроллеры двигателя SFC-LAC User Manual
Page 156

5. Commissioning
5−54
Festo GDCP−SFC−LACI−CO−EN en 0812NH
4. Homing (requires status 1.4 or 1.5)
Step/Description
Control bytes
Status bytes
Byte
B7
B6
B5
B4
B3
B2
B1
B0
Byte
B7 B6 B5 B4 B3
B2 B1
B0
4.1 Start homing
Byte 1
OPM2
OPM1
LOCK
ć
RESET BRAKE
STOP
ENABL
Byte 1
OPM2 OPM1
HMI
24VL
FAULT WARN
OPEN ENABL
4.1 Start homing
CCON 0
x
x
x
0
0
1
1
SCON 0
x
0
1
0
0
1
1
Byte 2
ć
CLEAR TEACH
JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV
TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
F
0
1
SPOS 0
0
0
0
0
0
1
1
4.2 Homing running
Byte 1
OPM2
OPM1
LOCK
ć
RESET BRAKE
STOP
ENABL
Byte 1
OPM2 OPM1
HMI
24VL
FAULT WARN
OPEN ENABL
4.2 Homing running
CCON 0
x
x
x
0
0
1
1
SCON 0
x
0
1
0
0
1
1
Byte 2
ć
CLEAR TEACH
JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV
TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
1
0
1
SPOS 0
0
0
1
0
0
1
1
4.3 Homing finished
Byte 1
OPM2
OPM1
LOCK
ć
RESET BRAKE
STOP
ENABL
Byte 1
OPM2 OPM1
HMI
24VL
FAULT WARN
OPEN ENABL
4.3 Homing finished
CCON 0
x
x
x
0
0
1
1
SCON 0
x
0
1
0
0
1
1
Byte 2
ć
CLEAR TEACH
JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV
TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
0
0
1
SPOS
1
0
0
0
0
1
0
1
0: Logic 0;
1: Logic 1;
x: not relevant (optional);
F: Edge positive
Tab. 5/7: Control and status bytes Homing"
Description to 4. Homing:
4.1
A positive edge at CPOS.B2 HOM starts homing. The
start is confirmed with SPOS.B1 ACK (Acknowledge
start) as long as CPOS.B2 HOM is set.
4.2
Movement of the axis is shown with SPOS.B4 MOV.
4.3
After successful homing, SPOS.B2 MC and
SPOS.B7 REF will be set.
If there are faults during homing:
} Fault handling: see example 3, Tab. 5/6.