Create readiness to operate ć record select, Commissioning 5−50 – Festo Контроллеры двигателя SFC-LAC User Manual
Page 152

5. Commissioning
5−50
Festo GDCP−SFC−LACI−CO−EN en 0812NH
1.Create readiness to operate ć Record select
Step/
D
i ti
Control bytes
Status bytes
Description
Byte
B7
B6
B5
B4
B3
B2
B1
B0
Byte
B7 B6 B5 B4 B3
B2 B1
B0
1.1 Basic status
Byte 1
OPM2
OPM1
LOCK
ć
RESET BRAKE
STOP
ENABL
Byte 1
OPM2 OPM1
HMI
24VL
FAULT WARN
OPEN ENABL
1.1 Basic status
(device control
CCON 0
0
0
0
0
0
0
0
SCON 0
0
0
1
0
0
0
0
(device control
HMI = off )
Byte 2
ć
CLEAR TEACH
JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV
TEACH
MC
ACK
HALT
HMI = off )
CPOS x
0
0
0
0
0
0
0
SPOS 0
0
0
0
0
1
0
0
1.2 Disable device
Byte 1
OPM2
OPM1
LOCK
ć
RESET BRAKE
STOP
ENABL
Byte 1
OPM2 OPM1
HMI
24VL
FAULT WARN
OPEN ENABL
1.2 Disable device
control by FCT/HMI
(optional)
CCON x
x
1
x
x
0
x
x
SCON x
x
0
x
x
x
x
x
(optional)
Byte 2
ć
CLEAR TEACH
JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV
TEACH
MC
ACK
HALT
CPOS x
x
x
x
x
x
x
x
SPOS x
x
x
x
x
x
x
x
1.3 Enable drive,
Byte 1
OPM2
OPM1
LOCK
ć
RESET BRAKE
STOP
ENABL
Byte 1
OPM2 OPM1
HMI
24VL
FAULT WARN
OPEN ENABL
1.3 Enable drive,
enable operation
CCON
0
0
x
x
0
0
1
1
SCON
0
0
0
1
0
0
1
1
(record selection)
Byte 2
ć
CLEAR TEACH
JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV
TEACH
MC
ACK
HALT
(record selection)
CPOS x
0
0
0
0
0
0
1
SPOS 0
0
0
0
0
1
0
1
0: Logic 0;
1: Logic 1;
x: not relevant (optional);
F: Edge positive
Tab. 5/4: Control and status bytes Creating readiness to operate ć Record selection"
Description of 1. Create readiness to operate:
1.1
Basic status of the drive when the supply voltage has
been switched on.
} Step 1.2 or 1.3
1.2
Optionally: Disable device control via FCT/HMI using
CCON.B5 = 1 (LOCK).
} Step 1.3
1.3
Enable drive in Record Select mode.
} Homing: Example 4, Tab. 5/7.
If there are faults after switching on or after setting CCON.B0
(ENABLE):
} Fault handling: see example 3, Tab. 5/6 and chapter 6.3
Error messages".