5 teach the axis zero point, Teach the axis zero point – Festo Контроллеры двигателя SFC-LAC User Manual
Page 119

5. Commissioning
5−17
Festo GDCP−SFC−LACI−CO−EN en 0812NH
5.2.5
Teach the axis zero point
Factory setting
Axis zero point with:
ć Homing to reference switch: 0 mm
ć Homing to negative fixed stop: +1 mm
ć Homing to a positive fixed stop: −1 mm
Note
Risk of overloading when homing to stop:
The drive must not press continuously against a mechanĆ
ical stop (excessive heating).
·
Make sure that the axis zero point is at least 1 mm away
from the mechanical stop.
This causes the drive to leave the mechanical stop after
recognising the reference point.
If necessary, teach the
axis zero point:
Warning
The drive will move during teaching.
·
Make sure that nobody can reach into the positioning
range of the moveable load and that there are no objects
in its path.
1. Select [Settings] [Axis parameter] [Zero point].
2. Move the drive manually to the desired axis zero point
using the arrow keys.
3. Accept the position reached with OK
4. Save the parameter settings in EEPROM with the
[SAVE]
menu command.
5. Perform homing again (see section 5.2.4). When homing is
concluded, the drive stands at the new axis zero point.
} Settings
Axis parameter
Zero point
SW–limit–neg
SW–limit–pos
SAVE