Parameter for homing – Festo Контроллеры двигателя SFC-LAC User Manual
Page 305

B. Parametrising as per FHPP−FPC
B−77
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Parameter for homing
Offset axis zero point
PNU
1010
ć
int32
rw
Description
Offset of the axis zero point AZ to the reference point REF in [increments]
(= distance from reference point). Factory settings: see chapter 5.2.5.
The drive is no longer referenced after the axis zero point has been modified.
CI / DS402
607Ch
00h
int32
rw
Homing method
PNU
1011
ć
uint8
rw
Description
Homing method.
Values
Function
1 (0x01):
Search for limit switch in negative direction with index search
2 (0x02):
Search for limit switch in positive direction with index search
7 (0x07):
Search for reference switch in positive direction with index search
11 (0x0B):
Search for reference switch in negative direction with index search
−18 (0xEE): Search for stop in positive direction
−17 (0xEF): Search for stop in negative direction
The drive is no longer referenced after the homing method has been modified.
CI / DS402
6098h
00h
uint8
rw
Homing velocities
PNU
1012
1...2
int32
rw
Description
Speeds during homing
Search REF
(search for REF)
1012
1
(search for REF)
Speed when searching for the reference point REF in [inc/s]
Search AZ
(search for AZ)
1012
2
(search for AZ)
Speed of travel to the axis zero point AZ in [inc/s]
CI / DS402
6099h
01h...02h
int32