5. Commissioning
5−63
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Overview of parameters involved (see also section B.3.9)
Parameters involved
Description
FCT
PNU
CI
Offset axis zero point
x
1010
607Ch
Homing method
x
1011
6098h
Homing speeds
x
1012
6099h
Homing required
ć
1014
23F6h
Maximum homing current
x
1015
23F7h
Start (FHPP)
CPOS.B2 = positive edge: start homing
Feedback (FHPP)
SPOS.B1 = positive edge: acknowledge start
SPOS.B7 = drive is referenced
Condition
Device control by PLC/fieldbus; controller in the Operation enabled"
status; no jogging command is present
Tab. 5/11: Parameters involved in homing
Homing methods
1)
Hex
Dec
Description
01h
1
Search for limit switch in negative direction with index search
02h
2
Search for limit switch in positive direction with index search
07h
7
Search for reference switch in positive direction with index search
0Bh
11
Search for reference switch in negative direction with index search
EFh
−17
Search for stop in a negative direction. The point found is the reference
position. As the axis must not stand still at the stop, the offset axis zero
point must be
š 0.
EEh
−18
Search for stop in a positive direction. The point found is the reference
position. As the axis must not stand still at the stop, the offset axis zero
point must be
š 0.
1)
For a detailed description of the homing methods, see section 1.1.6.
Tab. 5/12: Overview of homing methods