5. Commissioning
5−88
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Parameter / Description
CI
FCT
PNU
Out2: Use
Value
Out 2 is used as:
0
No function
1
Brake output (see 5.6.11)
2
Digital signal display (see FCT)
3
Output/Compare" (see FCT)
1250
x
2422/01h
Out 2: Setting condition
Value
The output is set dependent upon:
1
Position comparison
2
Force comparison
3
Speed comparison
4
Record number comparison
10h
Ready
11h
Motion complete
12h
Error
13h
Sample in
14h
(reserved)
15h
ON (during setting of this bit, the output is set immediately)
1251
x
2422/02h
Out 2: Resetting condition (delay: see 2422/08h)
Value
The output is reset dependent upon:
1
Position comparison + delay
2
Force comparison + delay
3
Speed comparison + delay
4
Record number comparison + delay
10h
Ready + delay
11h
Motion complete + delay
12h
Error + delay
13h
Sample in + delay
14h
Delay
15h
OFF (during setting of this bit, the output is reset immediately)
1252
x
2422/03h
Out 2: Value for setting condition
The saved value that when reached means that the comparison condition
is considered fulfilled in accordance with 2422/02h.
With record number comparison: bit number
Z record number:
bit 1 = record 1 (bit 0: do not use). Example: 0x6 = in record1 and also in
record2, the condition is considered fulfilled and the output is set.
1253
x
2422/04h
Out 2: Value for resetting condition
As above, but in accordance with 2422/03h for the resetting condition.
1254
x
2422/05h