Table of error messages

31h

CVE connection

Can be parameterised as:

E/-/-

Diagnostic memory: optional

A connection error has occurred during "Control via Ethernet" (CVE).

Check the connection: plug disconnected, cable lengths observed, shielded cable used, screening

connected?

Acknowledgement option: Error can only be acknowledged after eliminating the cause.

Parameterisable error response(s):

B, C, D, E, F, G

32h

FCT connection with master control

Can be parameterised as:

E/-/-

Diagnostic memory: optional

Connection to the FCT has been interrupted.

Check the connection and perform a reset if necessary.

For parameterisation as an error: The error can only be acknowledged after eliminating the cause.

Parameterisable error response(s):

B, C, D, E, F, G

33h

Output stage temperature warning

Can be parameterised as: -/

W/I

Diagnostic memory: optional

Temperature of output stage increased.

Check cylinder sizing.

Check motor and cabling for short circuits.

Check the mechanics for sluggishness.

Reduce the ambient temperature, improve heat dissipation.

For parameterisation as a warning: The warning disappears if the temperature is back below the

danger threshold.

34h

Save Torque Off (STO)

Can be parameterised as:

E/W/I

Diagnostic memory: optional

The “Safe Torque Off” safety function has been requested.

Please observe the separate documentation for the STO function.

For parameterisation as an error: The error can be acknowledged.

Parameterisable error response(s): 0

For parameterisation as a warning: The warning disappears if the STO is no longer requested.

37h

Standstill monitoring

Can be parameterised as: -/

W/I

Diagnostic memory: optional

The actual position is outside the downtime window. Parameterisation of the window may be too

narrow.

Check parameterisation of the downtime window.

For parameterisation as a warning: The warning disappears if the actual position is within the

standstill window again or a new record has been started

.