6
Diagnostics
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
99
Table of error messages
31h
CVE connection
Can be parameterised as:
E/-/-
Diagnostic memory: optional
A connection error has occurred during "Control via Ethernet" (CVE).
•
Check the connection: plug disconnected, cable lengths observed, shielded cable used, screening
connected?
–
Acknowledgement option: Error can only be acknowledged after eliminating the cause.
Parameterisable error response(s):
B, C, D, E, F, G
32h
FCT connection with master control
Can be parameterised as:
E/-/-
Diagnostic memory: optional
Connection to the FCT has been interrupted.
•
Check the connection and perform a reset if necessary.
–
For parameterisation as an error: The error can only be acknowledged after eliminating the cause.
Parameterisable error response(s):
B, C, D, E, F, G
33h
Output stage temperature warning
Can be parameterised as: -/
W/I
Diagnostic memory: optional
Temperature of output stage increased.
•
Check cylinder sizing.
•
Check motor and cabling for short circuits.
•
Check the mechanics for sluggishness.
•
Reduce the ambient temperature, improve heat dissipation.
–
For parameterisation as a warning: The warning disappears if the temperature is back below the
danger threshold.
34h
Save Torque Off (STO)
Can be parameterised as:
E/W/I
Diagnostic memory: optional
The “Safe Torque Off” safety function has been requested.
•
Please observe the separate documentation for the STO function.
–
For parameterisation as an error: The error can be acknowledged.
Parameterisable error response(s): 0
–
For parameterisation as a warning: The warning disappears if the STO is no longer requested.
37h
Standstill monitoring
Can be parameterised as: -/
W/I
Diagnostic memory: optional
The actual position is outside the downtime window. Parameterisation of the window may be too
narrow.
•
Check parameterisation of the downtime window.
–
For parameterisation as a warning: The warning disappears if the actual position is within the
standstill window again or a new record has been started
.