beautypg.com

Festo Электроцилиндр User Manual

Page 74

background image

5

Commissioning

74

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Requirements

Drive is referenced and ready.

Start record

Pre-select a record (e.g. RecNr = 3) and start with START. Ack and MC are reset.

Error

An error occurs, e.g. a following error. In this example, this malfunction has been parameterised as an

error and, as a response, a deceleration is effected with the quick stop ramp (Quick stop).

The outputs Ready and Error are reset.

The drive brakes with the quick stop ramp and remains stationary.

Acknowledge error

The error is acknowledged by setting the RESET input.

After setting this input the parameterised time for the switch-on delay of the holding brake starts to

run. When this time has expired the outputs Ready and Error are set again.

Restart

The record is restarted with a START signal and it travels the remaining path.