beautypg.com

2 calculation rules – Festo Электроцилиндр User Manual

Page 20

background image

2

Overview

20

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Measuring reference system

AZ

a

SLN

SLP

1 2 3

0

b

c

PZ

d

e

g

TP/AP

REF

b

c

a

d

REF

AZ

PZ

SLN

SLP

REF

Homing point (reference point)

a

Offset axis zero point

AZ

Axis zero point

b, c

Offset software end

positions

PZ

Project zero point

d

Offset project zero point

SLN

Negative software end position (software limit negative)

e

Usable stroke

SLP

Positive software end position (software limit positive)

TP/AP

Target position/actual position

g

Offset TP/AP to PZ

Tab. 2.2

Measuring reference system

2.6.2

Calculation rules

Dot

Calculation rule

Axis zero point

AZ

= REF + a

Project zero point

PZ

= AZ + d

= REF + a + d

Negative software end position

SLN

= AZ + b

= REF + a + b

Positive software end position

SLP

= AZ + c

= REF + a + c

Target position/actual position

TP, AP

= PZ + g

= AZ + d + g

= REF + a + d + g