beautypg.com

Festo Электроцилиндр User Manual

Page 121

background image

B

Control via Ethernet (CVE)

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

121

Condition for status transition

Description

18

Error

Operation enabled

The cause of the fault must be eliminated

(e.g. over-temperature reduced to permissible value).

Positive edge for CW.

FR (Error Reset)

CW.

PSOn (output stage on after Error reset) = 1

CW.

EO (Enable Operation) = 1

CW.

QS (Quick Stop) = 1

CW.

EV (Enable Voltage) = 1

CW.

SO (Switch on) = 1

19

Error

Switched on

The cause of the fault must be eliminated

(e.g. over-temperature reduced to permissible value).

Positive edge for

FR (Error Reset)

CW.

PSOn (output stage on after Error Reset) = 1

CW.

EO (Enable Operation) = 0

CW.

EV (Enable Voltage) = 1

CW.

SO (Switch on) = 1

Tab. B.8

Description of transitions

Control word (CVE object #2)

Bit

Abbreviation

Description

0

CW.SO

Switch on

1

CW.EV

Enable voltage

2

CW.QS

Quick stop

3

CW.EO

Enable operation

4

CW.ST

Start

5

Must always be 0.

6

CW.PSOn

Power stage on after reset

(Output stage on after error reset)

7

CW.FR

Error reset

8

CW.STP

STOP

9 … 31

Must always be 0.

Tab. B.9

Control word