beautypg.com

A.1 technical data – Festo Электроцилиндр User Manual

Page 105

background image

6

Diagnostics

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

105

6.4.4

Other problems and remedies

Problem

Cause and remedy

Controller does not

work at all

Check all cables and connections for short circuit, disconnections or

incorrect pin allocation.

Observe the information in the assembly instructions for the cables and

plugs used.

Blown internal fuse: Internal short circuit, completely replace the

controller.

Controller does not

achieve the specified

performance data

Incorrect control signals from master controller (incorrect signals,

incorrect level). Observe the timing diagrams in the Commissioning

chapter.

Incorrect controller setting. Observe the information in the online help

section of the FCT plug-in for the correct settings of the controller

parameters.

Error in the power supply. Observe the tolerance values in accordance

with the chapter “Technical data”.

Tab. 6.4

Other problems and remedies