4

Electrical installation

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

31

4

Electrical installation

4.1

Overview

Caution

Uncontrolled drive motion may cause personal injury and material damage

Switch off the

power supplies prior to any assembly, installation or maintenance

work and prevent them from being restarted accidentally.

Caution

Faulty pre-assembled lines may destroy the electronics and trigger unexpected move-

ments of the motor.

When wiring the system only use the supplied connectors and preferably the cables

that are listed as accessories (

Tab. 4.1).

Lay all flexible lines so that they are free of kinks and free of mechanical stress; if

necessary use chain link trunking.

If unused plug connectors are touched, there is a danger that damage may occur to the

CMMO or to other parts of the system as a result of electrostatic discharge (ESD). Place

protective caps on unused terminals to prevent such discharges.

Note

To ensure compliance with EMC safety:

The maximum length of the individual cables should not exceed 30 m.

The project engineering performance data relates to a maximum cable length of 10 m.

To ensure compliance with the IP protection class (if required):

Please note that the specified IP protection class is only achieved with a full plug

and cable assignment.