beautypg.com

Festo Электроцилиндр User Manual

Page 98

background image

6

Diagnostics

98

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Table of error messages

2Bh

Firmware update, invalid firmware

Can be parameterised as:

E/W/-

Diagnostic memory: optional

The firmware update process could not be performed. The firmware version is incompatible with the

hardware used.

Ascertain the version of your hardware. You can ascertain the compatible firmware versions and

download the appropriate firmware from the Festo website.

For parameterisation as an error: The error can only be acknowledged after eliminating the cause.

Parameterisable error response(s):

A

For parameterisation as a warning: The warning disappears if a new FW download process is

started.

2Dh

I²t warning motor

Can be parameterised as: -/

W/I

Diagnostic memory: optional

The I²t integral is up to 80% full.

You can parameterise this message as a warning or suppress it completely as information.

For parameterisation as a warning: The warning disappears if the I²t integral is below 80%.

2Eh

Index pulse too close on proximity sensor

Can be parameterised as:

E/-/-

Diagnostic memory: optional

The switching point of the proximity sensor is too close to the index pulse. In some cases, this can

mean that no reproducible homing position can be determined.

Observe the special section 6.4.5 for this error.

Move the homing switch/limit switch to the axis. You can display the distance between the switch

and index pulse in the FCT.

Acknowledgement option: Error can only be acknowledged after eliminating the cause.

Parameterisable error response(s):

B, C, E, F

2Fh

Following error

Can be parameterised as:

E/W/I

Diagnostic memory: optional

The following error is too large. This error can occur during positioning and speed modes.

Enlarge error window.

Acceleration, speed, jerk or load too high? Mechanics stiff?

Motor overloaded (current limitation from I²t monitoring active?)

For parameterisation as an error: The error can be acknowledged.

Parameterisable error response(s): B, C,

E, F

For parameterisation as a warning: The warning disappears if the following error is back within the

permissible range.