Festo Электроцилиндр User Manual
Page 115
B
Control via Ethernet (CVE)
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
115
Confirmation (acknowledge)
Ack
Description
Remedy
0x00
Everything ok.
–
0x01
Service is not supported.
Check the service ID of the request.
0x03
User data length of the request is invalid.
Check the structure of the request.
0xA0
Range of values of another CVE object violated.
Writing the CVE object would cause the
range of values of another CVE object
to be violated. (The other object uses
this CVE object as a minimum or
maximum).
0xA2
Invalid object index.
Correct the object index.
0xA4
The CVE object cannot be read.
–
0xA5
The CVE object cannot be written.
–
0xA6
The CVE object cannot be written while the drive
is in an “Operation enabled” status.
Quit the “Operation enabled” status.
0xA7
The CVE object must not be written without
higher-order control.
Assign higher-order control to the
CVE interface. Use CVE object #3 for
this purpose.
0xA9
The CVE object cannot be written, as the value is
lower than the minimum value.
Correct the value.
0xAA
The CVE object cannot be written, as the value is
greater than the maximum value.
Correct the value.
0xAB
The CVE object cannot be written, as the value is
not within the valid value set.
Correct the value.
0xAC
The CVE object cannot be written, as the
specified data type is incorrect.
Correct the data type.
0xAD
The CVE object cannot be written, as it is
password protected.
Remove password protection via FCT.
Tab. B.6
Confirmation (acknowledge)