beautypg.com

Festo Электроцилиндр User Manual

Page 94

background image

6

Diagnostics

94

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Table of error messages

14h

Negative direction locked

Can be parameterised as:

E/-/-

Diagnostic memory: optional

A limit switch error or a software limit position error has occurred and subsequently a movement in

the blocked direction has been initiated.

Check the target data.

Check positioning area.

This error can only be acknowledged if the drive is within the valid movement range. If necessary,

start a corresponding position set or move the drive by using the jog function. Movements in a

negative direction are blocked.

Acknowledgement option: Error can only be acknowledged after eliminating the cause.

Parameterisable error response(s): A,

B, C, E, F

15h

Output stage temperature exceeded

Can be parameterised as:

E/-/-

Diagnostic memory: optional

The permissible limit value for the output stage temperature has been exceeded. The output stage is

possibly overloaded.

This error can only be acknowledged if the temperature is within the permissible range.

Check cylinder sizing.

Check motor and cabling for short circuits.

Check the mechanics for sluggishness.

Reduce the ambient temperature, improve heat dissipation.

Acknowledgement option: Error can be acknowledged.

Parameterisable error response(s): A, B,

C, D

16h

Output stage temperature too low

Can be parameterised as:

E/-/-

Diagnostic memory: optional

The ambient temperature is below the permissible range.

Increase the ambient temperature. This error can only be acknowledged if the temperature is

within the permissible range.

Acknowledgement option: Error can be acknowledged.

Parameterisable error response(s): A, B,

C, D

17h

Logic voltage exceeded

Can be parameterised as:

E/-/-

Diagnostic memory: optional

The logic power supply monitor has detected an overvoltage. This is either due to an internal defect

or an excessive supply voltage.

Check external supply voltage directly on the device.

If the error is still present after a reset has been conducted, it means there is an internal defect

and the device has to be replaced.

Acknowledgement option: Error can be acknowledged.

Parameterisable error response(s): A,

B