3 safety in the network, 4 timeout – Festo Электроцилиндр User Manual
Page 42
5
Commissioning
42
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
After making changes to the network configuration of the CMMO-ST, it will need to be
restarted in order for the changes to take effect.
5.2.3
Safety in the network
Caution
When connecting the CMMO-ST to existing networks (e.g. the Internet): any unauthor-
ised or accidental access to the CMMO-ST could result in unforeseeable behaviour.
•
Only use the CMMO-ST in subnets that are protected from external unauthorised
access, e.g. by using network security components (special
gateways/firewalls).
Use a password if you want to prevent accidental access to the CMMO-ST (in FCT: menu
option “Component” / Online / Password).
5.2.4
Timeout
The CMMO-ST detects if the connection to the FCT software has been interrupted and it behaves in
accordance with the settings parameterised in FCT under “Error management” (error number 0x32).
The timeout period is typically 1 s, but it can be longer in slow networks, as the timeout period is
dynamically adapted to the transmission rate.
Caution
The CMMO-ST cannot detect if the connection to the web browser has been interrupted.
Movements that have been started via the web browser can
no longer be stopped by
using the web browser if the Ethernet connection is interrupted during the movement.
•
Only use the web browser if you are sure that accidental movements will not result in
any damage.