beautypg.com

7 encoder [x2, 8 motor [x6 – Festo Электроцилиндр User Manual

Page 38

background image

4

Electrical installation

38

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

4.7

Encoder [X2]

An incremental encoder with signals in accordance with

RS422 can be connected at connection X2.

Port

Pin

Function

X2

1

8

1

8

1

A/

1)

Incremental encoder signal A+,

Positive polarity

2

A/

1)

Incremental encoder signal A–,

Negative polarity

3

B/

1)

Incremental encoder signal B+,

Positive polarity

4

B/

1)

Incremental encoder signal B–,

Negative polarity

5

N/

1)

Increment encoder signal zero pulse,

positive polarity

6

N/

1)

Increment encoder signal zero pulse,

negative polarity

7

5 V (± 10 %)

Supply of the encoder.

Max. 100 mA permissible.

Not protected against short circuits.

8

0 V

Reference potential

1)

Each 5 V and Ri = approx. 120 Ω

Tab. 4.7

Connection X2 encoder

4.8

Motor [X6]

Port

Pin

Function

X6

1

6

1

6

1

String A

Connection of the two motor strings

2

String A/

3

String B

4

String B/

5

BR+

Connection of the holding brake

Short circuit and overload-proof.

24 V, max. 1.4 A

33 W.

BR– = GND,

BR+ is switched (24 V load)

6

BR–

Tab. 4.8

Connection X6 motor