A

Technical appendix

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

107

A

Technical appendix

A.1

Technical data

General

Protection class of the entire system according to

EN 60529

IP40 (with full pin allocation)

Pollution degree

2 (per EN 50178)

Ambient temperature

Operation: 0 ... +50 °C

Storage/transport: –25 … +75 °C

Relative air humidity (at 25 °C)

0 … 90 %, non-condensing

Max. installation height

< 2000 m above sea level

Weight

290 g

Electromagnetic compatibility (EMC)

1)

Declaration of conformity (www.festo.com)

Vibration

Checked in accordance with DIN EN 60068 part 2-6

With wall mounting: severity level 2

With H-rail mounting: severity level 1

Shock

Checked in accordance with DIN EN 60068 part 2-27

With wall mounting: severity level 2

With H-rail mounting: severity level 1

Continuous shock test

Checked in accordance with DIN EN 60068 part 2-29

With wall and H-rail mounting:

Severity level 1

1)

The component is solely intended for use in industrial environments. Maximum length of the individual connecting cables: 30 m.

The project planning performance data relates to a maximum cable length of 10 m.

Key safety data and certifications can be found in the separate STO documentation for

the CMMO-ST.

Requirements for observing the certified

UL conditions if the product is operated in the

USA or Canada can be found in the separate special UL documentation.