5

Commissioning

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

85

5.9.4

Time comparators

The message “Time comparator active” is set when the following condition is fulfilled:

The time since the start of the record is within the parameterisable limits

(

› minimum and š maximum).

In all other cases the message is inactive.

Overview of parameters for time comparators

FCT

Lower time limit (minimum)

1)

x

Upper time limit (maximum)

1)

x

Feedback

You can allocate this signal to digital output 6 or 7 in FCT on the “Digital I/O” panel.

1)

The limit values can only be positive. If the minimum value is greater than the maximum value, the condition for the time

comparator is never fulfilled.