beautypg.com

4 i/o interface [x1 – Festo Электроцилиндр User Manual

Page 35

background image

4

Electrical installation

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

35

4.4

I/O interface [X1]

Communication with the higher-order controller (PLC/IPC) occurs via the I/O interface.

Connection to the CMMO

1

14

25

13

X1

PNP

NPN

24

25

Pin

1

2

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

I/O

1

2

11

1

2

3

4

5

6

7

8

9

10

11

+24 V

0 V

Inputs

Outputs

Out

GND

Tab. 4.3

Port X1

Pin 24 and pin 25 can be used to switch an input (

illustration in Tab. 4.3):

PNP version: Pin 24 at input

NPN version: Pin 25 at input

Caution

Damage to the device

Pin 24 and pin 25 are not short circuit proof.

The functional description of the I/O interface, dependent on the selected profile, can be

found in the Commissioning chapter.