6

Diagnostics

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

87

6

Diagnostics

6.1

Types of malfunction

Malfunctions can have different levels of severity:

Error

An error always results in an error response. The possible error responses are listed in section 6.4.1.

Errors must be acknowledged, i.e. reset. In terms of the CMMO-ST, errors can only be reset when their

cause has been eliminated.

Warning

Warnings have no influence on the behaviour of the drive and do not need to be acknowledged. The

cause of the warning should be eliminated in order that it does not lead to a malfunction.

Information

If an error message has been parameterised as “information”, it will not appear in the 7-segment

display. It is written into the diagnostic memory, however, depending on parametrisation.

6.2

7-segment display

The 7-segment display on the CMMO-ST provides information about operating modes, errors and

warnings. 4 characters are fundamentally displayed in succession, followed by a space.

1

1 Point for wave function
Fig. 6.1

7-segment display

The numbers of error messages are displayed in

hexadecimal format. Table of error messages

section 6.4.2.

Wave function

The point flashes if the radio button “Identify this CMMO: on” has been clicked on the CMMO website

(

section 5.3). This enables you to identify a certain CMMO-ST amongst a group of several units

(the connected CMMO-ST “waves”).

This wave function can also be activated from the FCT: Select the menu option “Component / FCT Inter-

face” and then click the “Search” button in the “FCT Interface” dialogue window to start the “Festo

Device Tool”. Then use the context menu of the CMMO-ST that has been located by the network scan to

select the option “Identification On/Off ”.