B

Control via Ethernet (CVE)

120

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Condition for status transition

Description

10

Switched on

Switch on disabled

CW.

FR (Error Reset) = 0

CW.

EV (Enable Voltage) = 0

or:

CW.

FR (Error Reset) = 0

CW.

QS (Quick Stop) = 0

CW.

EV (Enable Voltage) = 1

11

Operation enabled

Quick Stop active

CW.

FR (Error Reset) = 0

CW.

QS (Quick Stop) = 0

CW.

EV (Enable Voltage) = 1

12

Quick Stop active

Switch on disabled

CW.

FR (Error Reset) = 0

CW.

EV (Enable Voltage) = 0

13

From anywhere to:

Error reaction active

Release of an error response by the error management

system. The status transition is independent of the control

signals currently being sent.

14

Error reaction active

Error

Execution of the error response is complete. Automatic

change of state to Error.

15

Error

Switch on disabled

The cause of the error must be eliminated (e.g. overheat-

ing, temperature reduced to permissible level).

Positive edge for

FR (Error Reset).

CW.

PSOn (output stage on after Error Reset) = 0

At least one of the following bits is

not set to 1:

CW.

EO (Enable Operation)

CW.

QS (Quick Stop)

CW.

EV (Enable Voltage)

CW.

SO (Switch on)

16

Quick Stop active

Operation enabled

CW.

FR (Error Reset) = 0

CW.

EO (Enable Operation) = 1

CW.

QS (Quick Stop) = 1

CW.

EV (Enable Voltage) = 1

CW.

SO (Switch on) = 1

17

Ready to switch on

Operation enabled

CW.

FR (Error Reset) = 0

CW.

EO (Enable Operation) = 1

CW.

QS (Quick Stop) = 1

CW.

EV (Enable Voltage) = 1

CW.

SO (Switch on) = 1