5

Commissioning

56

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Assigning the inputs and outputs

Valve profile: Inputs

Input

Designation

Description

1

Position record 1

1)

Start and execute position record 1 as long as input 1 remains

active.

2

Position record 2

1)

Start and execute position record 2 as long as input 2 remains

active.

3 … 6

1)

7

Position record 7

1)

Start and execute position record 7 as long as input 7 remains

active.

8

REF

Starts a homing run in accordance with the parameterised

method.

9

BRAKE

An active input overrides automatic brake control and opens the

closed brake. This input can be used to open a closed brake,

however, it cannot be used to close an open brake (prevention of

brake wear as a result of faulty application).

10

ENABLE

After setting this enable signal the CMMO-ST assumes control of

the connected drive.

11

RESET

A reported error is reset (if possible).

1)

If the drive is not referenced at the start of a position record, a homing run can be started automatically

section 2.7.5.

Tab. 5.3