Sntp client poll timer – Allied Telesis AT-S94 CLI (AT-8000S Series) User Manual
Page 77

Clock Commands
Page 76
Default Configuration
No keys are trusted.
Command Mode
Global Configuration mode
User Guidelines
The command is relevant for both received Unicast and Broadcast.
If there is at least 1 trusted key, then unauthenticated messages will be ignored.
Example
The following example authenticates key 8.
sntp client poll timer
The sntp client poll timer Global Configuration mode command sets the polling time for the Simple Network
Time Protocol (SNTP) client. Use the no form of this command to return to default configuration.
Syntax
sntp client poll timer seconds
no sntp client poll timer
Parameters
•
seconds — Polling interval in seconds (Range: 60-86400)
Default Configuration
Polling interval is 1024 seconds.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example sets the polling time for the Simple Network Time Protocol (SNTP) client to 120 seconds.
Console(config)# sntp authentication-key 8 md5 ClkKey
Console(config)# sntp trusted-key 8
Console(config)# sntp authenticate
Console(config)# sntp client poll timer 120