background image

VLAN Commands

Page 346

Command Mode

Interface Configuration (VLAN) mode. Cannot be configured for a range of interfaces (range context).

User Guidelines

There are no user guidelines for this command.

Example

The following example gives VLAN number 19 the name Marketing.

switchport protected

The switchport protected Interface Configuration mode command enables Private VLAN Edge, by overriding the
FDB decision, and sends all Unicast, Multicast and Broadcast traffic to an uplink port. Use the no form of this
command to disable overriding the FDB decision.

Syntax

switchport protected {ethernet port | port-channel port-channel-number }

no switchport protected

Parameters

port— Specifies the uplink Ethernet port.

port-channel-number — Specifies the uplink port-channel.

Default Configuration

Switchport protected is disabled.

Command Mode

Interface Configuration (Ethernet, port-channel) mode

User Guidelines

Private VLAN Edge (PVE) supports private communication by isolating PVE-defined ports and ensuring that all
Unicast, Broadcast and Multicast traffic from these ports is only forwarded to uplink port(s).

PVE requires only one VLAN on each device, but not on every port; this reduces the number of VLANs required
by the device. Private VLANs and the default VLAN function simultaneously in the same device.

The uplink must be a GE port.

console(config)# interface vlan 19

console(config-if)# name Marketing