Power over Ethernet Commands
Page 212
The following table describes the significant fields shown in the example:
3/e1
Auto
Low
Off
N/A
console# show power inline ethernet 4/e1
Port
Powered
Device
State
Status
Priority
Class
----
-------
-----------
-------------
------------
--------
4/e1
Auto
On
low
class1
Overload Counter: 0
Short Counter: 0
Denied Counter: 0
Absent Counter: 1
Invalid Signature Counter: 0
F i e l d
D e s c r i p t i o n
Power
The operational status of the inline power sourcing equipment.
Nominal Power
The nominal power of the inline power sourcing equipment in Watts.
Consumed Power
Measured usage power in Watts.
Usage Threshold
The usage threshold expressed in percents for comparing the measured power
and initiating an alarm if threshold is exceeded.
Traps
Indicates if inline power traps are enabled.
Port
The Ethernet port number.
Powered Device
Description of the powered device type.
State
Indicates if the port is enabled to provide power. Can be: Auto or Never.
Priority
The priority of the port from the point of view of inline power management. Can
be: Critical, High or Low.
Status
Describes the inline power operational status of the port. Can be: On, Off, Test-
Fail, Testing, Searching or Fault.
Classification
The power consumption range of the powered device. Can be: 0.44 – 12.95,
0.44 – 3.84, 3.84 – 6.49 or 6.49 – 12.95.
Overload Counter
Counts the number of overload conditions that has been detected.
Short Counter
Counts the number of short conditions that has been detected.
Denied Counter
Counts the number of times power has been denied.
Absent Counter
Counts the number of times power has been removed because powered device
dropout was detected.
Invalid Signature Counter
Counts the number of times an invalid signature of a powered device was
detected.