Power over Ethernet Commands

Page 212

The following table describes the significant fields shown in the example:

3/e1

Auto

Low

Off

N/A

console# show power inline ethernet 4/e1

Port

Powered

Device

State

Status

Priority

Class

----

-------

-----------

-------------

------------

--------

4/e1

Auto

On

low

class1

Overload Counter: 0

Short Counter: 0

Denied Counter: 0

Absent Counter: 1

Invalid Signature Counter: 0

F i e l d

D e s c r i p t i o n

Power

The operational status of the inline power sourcing equipment.

Nominal Power

The nominal power of the inline power sourcing equipment in Watts.

Consumed Power

Measured usage power in Watts.

Usage Threshold

The usage threshold expressed in percents for comparing the measured power
and initiating an alarm if threshold is exceeded.

Traps

Indicates if inline power traps are enabled.

Port

The Ethernet port number.

Powered Device

Description of the powered device type.

State

Indicates if the port is enabled to provide power. Can be: Auto or Never.

Priority

The priority of the port from the point of view of inline power management. Can
be: Critical, High or Low.

Status

Describes the inline power operational status of the port. Can be: On, Off, Test-
Fail, Testing, Searching or Fault.

Classification

The power consumption range of the powered device. Can be: 0.44 – 12.95,
0.44 – 3.84, 3.84 – 6.49 or 6.49 – 12.95.

Overload Counter

Counts the number of overload conditions that has been detected.

Short Counter

Counts the number of short conditions that has been detected.

Denied Counter

Counts the number of times power has been denied.

Absent Counter

Counts the number of times power has been removed because powered device
dropout was detected.

Invalid Signature Counter

Counts the number of times an invalid signature of a powered device was
detected.