beautypg.com

Sntp authentication-key – Allied Telesis AT-S94 CLI (AT-8000S Series) User Manual

Page 75

background image

Clock Commands

Page 74

User Guidelines

In both the date and recurring forms of the command, the first part of the command specifies when summer time
begins, and the second part specifies when it ends. All times are relative to the local time zone. The start time is
relative to standard time. The end time is relative to summer time. If the starting month is chronologically after the
ending month, the system assumes that the device is in the southern hemisphere.

USA rule for daylight savings time:

Start: Second Sunday in March

End: First Sunday in November

Time: 2 am local time

EU rule for daylight savings time:

Start: Last Sunday in March

End: Last Sunday in October

Time: 1.00 am (01:00)

Example

The following example sets summer time starting on the first Sunday in April at 2 am and finishing on the last
Sunday in October at 2 am.

sntp authentication-key

The sntp authentication-key Global Configuration mode command defines an authentication key for Simple
Network Time Protocol (SNTP). Use the no form of this command to remove the authentication key for SNTP.

Syntax

sntp authentication-key number md5 value

no sntp authentication-key number

Parameters

number — Key number (Range: 1-4294967295)

value — Key value (Range: 1-8 characters)

Default Configuration

No authentication key is defined.

Command Mode

Global Configuration mode

User Guidelines

Multiple keys can be generated.

Console(config)# clock summer-time recurring first sun apr 2:00 last sun oct 2:00