beautypg.com

Show copper-ports cable-length – Allied Telesis AT-S94 CLI (AT-8000S Series) User Manual

Page 201

background image

PHY Diagnostics Commands

Page 200

Default Configuration

This command has no default configuration.

Command Mode

User EXEC mode

User Guidelines

The maximum length of the cable for the TDR test is 120 meter.

Example

The following example displays information on the last TDR test performed on all copper ports.

show copper-ports cable-length

The show copper-ports cable-length User EXEC mode command displays the estimated copper cable length
attached to a port.

Syntax

show copper-ports cable-length [interface]

Parameters

interface — A valid Ethernet port. (Full syntax: unit/port)

Default Configuration

This command has no default configuration.

Command Mode

User EXEC mode

User Guidelines

The port must be active and working in 100M or 1000M mode.

console> show copper-ports tdr

Port

Result

Length [meters]

Date

----

------

---------------

----

1/e1

OK

1/e2

Short

50

13:32:00 23 July 2005

1/e3

Test has not been performed

1/e4

Open

64

13:32:00 23 July 2005

1/e5

Fiber

-

-