A Appendix - Marking codes

A.1 ATEX Marking

Fig. 139

П

РР

2

G

Ex d

ÐÐC

T6

Tfi -40°C to +60°C

Gb

Group (surface

device, no mining)

Category (high

protection degree,

the device in this

category can be

installed in zones

1 and 2)

Gas

Explosion-proof

housing for po-

tentially explosive

environments

Gas group

Gas temperature

classification

Installation temperature range

Protection level

of the equipment

for gas

П

РР

2

D

Ex tb

ÐÐÐC

T85°C

Tfi -40°C to +60°C

Db

Group (surface

device, no mining)

Category (high

protection degree,

the device in this

category can be

installed in zones

21 and 22)

Dusts

Dust ignition pro-

tection for zone

types 21-22

Dust group

Maximum surface

temperature for

dusts

Installation temperature range

Protection level

of the equipment

for dust

IP66

IP protection

degree

Tab. 19