A appendix - marking codes, A.1 atex marking, Ip66 – Videotec MAXIMUS MPXT User Manual
Page 87

Instruc
tions manual - English - EN
85
A Appendix - Marking codes
A.1 ATEX Marking
Fig. 139
П
РР
2
G
Ex d
ÐÐC
T6
Tfi -40°C to +60°C
Gb
Group (surface
device, no mining)
Category (high
protection degree,
the device in this
category can be
installed in zones
1 and 2)
Gas
Explosion-proof
housing for po-
tentially explosive
environments
Gas group
Gas temperature
classification
Installation temperature range
Protection level
of the equipment
for gas
П
РР
2
D
Ex tb
ÐÐÐC
T85°C
Tfi -40°C to +60°C
Db
Group (surface
device, no mining)
Category (high
protection degree,
the device in this
category can be
installed in zones
21 and 22)
Dusts
Dust ignition pro-
tection for zone
types 21-22
Dust group
Maximum surface
temperature for
dusts
Installation temperature range
Protection level
of the equipment
for dust
IP66
IP protection
degree
Tab. 19