7.1.2 Safety rules

Given the considerable weight of the system, use an

appropriate transport and handling system.
Before starting any operation, make sure the power

supply is disconnected.
Before powering the system, install an overload

protection device in the electrical equipment for the

building.
Make sure that all precautions for personal safety

have been taken.
Installation of the electrical equipment must comply

with the local legislation in force.
The device must be installed only and exclusively by

qualified technical personnel.

7.1.3 Explosion prevention rules

Use appropriate tools for the area in which you are

working.
Always remember that the device must be connected

to an appropriate earth conductor.
Before doing any technical work or maintenance

on the device, make sure that potentially explosive

atmosphere is not present.
Before starting any operation, make sure the power

supply is disconnected.
Do not open any kind of cap if there is a possibility of

your being in a potentially explosive atmosphere.
Make all connections, installation and maintenance

work in a non-explosive atmosphere.
The only cap that the installer have to remove is the

junction box cap. Keep any other cap tightly closed.

8 Switching on

The automatic pre-heating (de-ice) process

could be started whenever the device is

switched on and the air temperature is

below 0°C. This process is used to ensure

that the device works properly even at

low temperatures. The duration ranges

between 60 and 120 minutes, depending

on conditions.

The unit is switched on by simply connecting the

power supply, and switched off by disconnecting the

power.

8.1 Before powering the device in

an explosive atmosphere

Make sure that the unit and other

components of the installation are closed

so that it is impossible to come into contact

with live parts.

Make sure that the junction box cap is

properly and tightly closed.

Make sure (if present) that the sealing of

the seal fitting is properly carried out and

that the sealing compound is completely

cured and hardened.

Make sure that the device has been

connected to an earth link as described.

Make sure that all parts are fastened down

firmly and safely.