5 electrical rating, 6 cable glands, 5 electrical rating 14.6 cable glands – Videotec MAXIMUS MPXT User Manual
Page 79

Instruc
tions manual - English - EN
77
14.5 Electrical rating
ELECTRICAL RATING
Power Supply
Normal usage to be specified on product label
Short term de-icing cicle. Peak maintaining a mini-
mum internal temp at 5°C
230Vac
0.11A, 50/60Hz, 25.3W
0.52A, 50/60Hz, 120W
24Vac
1.08A, 50/60Hz, 25.9W
5A, 50/60Hz, 120W
120Vac
0.21A, 50/60Hz, 25.2W
1A, 50/60Hz, 120W
Tab. 12
14.6 Cable glands
SELECTION TABLE FOR CABLE GLANDS
Zone, Gas
Cable gland
type
Certification
Operating
temperature
Cable
Cable glands
part code
Diameter of
the external
cable (mm)
Under armor
cable diame-
ter (mm)
IIC, Zone 1 or
Zone 2
IIB or IIA,
Zone 1
Barrier
IECEX/ATEX/
GOST
-60 / +80°C
(-76°F /
+176°F)
Not armored
OCTEXB3/4C
13 - 20.2
Armored
OCTEXBA3/4C 16.9 - 26
IIB or IIA,
Zone 2
With gasket
IECEX/ATEX/
GOST
-60 / +100°C
(-76°F /
+212°F)
Not armored
OCTEX3/4C
13 - 20.2
Armored
OCTEXA3/4C
16.9 - 26
11.1 - 19.7
ATEX
-20 / +80°C
(-4°F / + 176°F)
Not armored
OCTEX3/4
14 - 17
Armored
OCTEXA3/4
18 - 23
14 - 17
Tab. 13