Flexicoil Flexcontrol

PF3000

Application Rate Mode

Ag Leader Technology

April 2002

2-82

Actual Rate Scale Factor: This setting is required to prevent data
loss in the log file (YLD file) when the units/sec of application get
above 3. Use the chart below for setting. The rate actually applied
and rate displayed on PF is unaffected by this setting. When the
log file is mapped in Ag Leader's SMS mapping program, the
mapped actual rate will be 1/10

th

of the real rate if the Actual Rate

Scale Factor is 0100. If it is 0.010, the mapped actual rate will be
1/100

th

the real rate. The mapped actual rate can be scaled back up

in SMS. The summary actual rate in SMS is unaffected by this
setting.


Avg. Speed

Swath

Application Rate between

Scale Factor

0-25 mph

0-80 ft

0-10 units/ac

1.000

0-10 mph

0-80 ft

11-100 units/ac

1.000

11-15 mph

0-50 ft

11-100 units/ac

1.000

11-15 mph

51-80 ft

11-100 units/ac

0.100

16-25 mph

0-80 ft

11-100 units/ac

0.100

0-25 mph

0-80 ft

101-500 units/ac

0.100

0-10 mph

0-80 ft

501-1000 units/ac

0.100

11-15 mph

0-50 ft

501-1000 units/ac

0.100

11-15 mph

51-80 ft

501-1000 units/ac

0.010

16-25 mph

0-80 ft

501-1000 units/ac

0.010

0-25 mph

0-80 ft

1001+ units/ac

0.010

2.

Press CONTRLER SETTINGS key. Set the following:

Controller Channel: This is the channel the PF will use to record
the actual rate and control the rate if desired. Set to either:

Air Tank 1
Air Tank 2
Air Tank 3
Sprayer 1
Sprayer 2

NOTE: The PF will not work with channels used
for planting.