beautypg.com

Pf3000, New leader controller, Ag leader technology – Ag Leader PF3000 Harvest & Application Operators Manual User Manual

Page 90: Application rate mode

background image

New Leader Controller

PF3000

Application Rate Mode

Ag Leader Technology

April 2002

2-74


Setup for New
Leader Mark III
or Mark IV
controllers


Complete the following steps to setup for New Leader Mark III or Mark
IV.

A separate configuration of settings should be created for every product
applied. A maximum of 16 different configurations can be created. The
screen below illustrates two configurations set up for a Mark IV.

1.

Press SETUP key. Press APP RATE CONFIG key. A screen
similar to the one below should appear:

APP RATE CONFIG

PRODUCT

CONTROLLER

CHANNEL

Lime

Mark IV

N/A

Fertilizer

Mark IV

N/A

EDIT

SETTINGS

CREATE

NEW

DELETE

EXIT

Press CREATE NEW key to set up a new configuration or select an
existing configuration and press the EDIT SETTINGS key. A new
screen appears with the following settings. Select each setting and
press EDIT key to change the settings.

Controller Make: Set to NEW LEADER.

Controller Model: Set to MARK III or MARK IV

Product: Press EDIT key. You can select an existing product and
press ACCEPT key or create a new product by pressing CREATE
NEW key. Press EDIT NAME key and enter name of product. Use
Left or Right Arrow keys to select a character. Use Up or Down
Arrow key to change the character. To erase a character in the name,
highlight that character and use UP or DOWN ARROW key to scroll
to the blank space between "9" and "A". Set every character and
press ACCEPT key twice.