DICKEY-john Land Manager

PF3000

Application Rate Mode

Ag Leader Technology

April 2002

2-58

Example: Tgt file in pints/ac of Treflan, Land Manager
applies based on gallons/ac. If tank mix is 1 pint of Treflan /
10 gallon water, then set to 1:10.0000. The PF will read the
pints/acre rate out of the .tgt file, multiply it by ten to convert
it to gallons/ac and send that rate to the Land Manager
console as the rate to be applied.

Target Rate Increment: Determines increment value by

which you can change the manual target rate with each press
of Up or Down arrow keys. Choices are 0.1, 1.0, 10.0, 100.0,
500.0, 1000.0, 5000.0 or 10000.0.

Actual Rate Scale Factor: This setting is required to prevent
data loss in the log file (YLD file) when the units/sec of
application get above 3. Use the chart below for setting. The
rate actually applied and rate displayed on PF is unaffected by
this setting. When the log file is mapped in Ag Leader's SMS
mapping program, the mapped actual rate will be 1/10

th

of the

real rate if the Actual Rate Scale Factor is 0.100. If it is
0.010, the mapped actual rate will be 1/100

th

the real rate.

The mapped actual rate can be scaled back up in SMS. The
summary actual rate in SMS is unaffected by this setting.

Avg. Speed

Swath

Application Rate between

Scale Factor

0-25 mph

0-80 ft

0-10 units/ac

1.000

0-10 mph

0-80 ft

11-100 units/ac

1.000

11-15 mph

0-50 ft

11-100 units/ac

1.000

11-15 mph

51-80 ft

11-100 units/ac

0.100

16-25 mph

0-80 ft

11-100 units/ac

0.100

0-25 mph

0-80 ft

101-500 units/ac

0.100

0-10 mph

0-80 ft

501-1000 units/ac

0.100

11-15 mph

0-50 ft

501-1000 units/ac

0.100

11-15 mph

51-80 ft

501-1000 units/ac

0.010

16-25 mph

0-80 ft

501-1000 units/ac

0.010

0-25 mph

0-80 ft

1001+ units/ac

0.010

2.

Press CONTRLER SETTINGS key. Set the following:

Controller Operating Mode: Set to liquid, granular or NH

3

whichever type the Land Manager console is controlling.