beautypg.com

Pf3000, Ag leader technology – Ag Leader PF3000 Harvest & Application Operators Manual User Manual

Page 185

background image

PF3000

Display Items

Ag Leader Technology

Application Rate Mode

April 2002

4-45

Application Rate
Display Items

Below are listed in order the available display items for the application rate
mode.

TARGET RATE

This displays the target rate value that is sent to the controller device. It
also indicates whether the target rate is on or off. You can also change
between an auto and man (short for manual) target rate.

ACTUAL RATE
This displays the instantaneous actual application rate. If the vehicle is not
moving and the application equipment is shut off, this will display the
average actual application rate.

AREA

SWATH
Swath will be zero until application starts. This displays the full swath of
set up for the active product/controller configuration.

TOTAL UNITS
This displays the total amount of the product that has been applied.

GROUND SPEED

AREA PER HR

DISTANCE

ACTUAL GPM
This is instantaneous gallons per minute that is measured by your flow
meter. This is a meaningless number if you are planting or fertilizing.

ACTUAL GPA
This is the instantaneous actual gallons per acre value that you are applying
and your sprayer controller is controlling. If you are planting or applying
fertilizer, this is a meaningless number.

CONV. TGT RATE
This displays the target rate stored in the .tgt prescription file. This will be
the same rate as the Target Rate display item only when Tgt Units:
Controller Units setting is 1:1.0000.