Pf3000, Rawson accu-rate/accu-plant, Ag leader technology – Ag Leader PF3000 Harvest & Application Operators Manual User Manual
Page 86
Rawson Accu-Rate/Accu-Plant
PF3000
Application Rate Mode
Ag Leader Technology
April 2002
2-70
Nominal Rate: If the PF is not controlling the rate, ignore this setting. If
the PF is controlling the rate, this setting must equal the nominal rate
setting in the Rawson processor.
Press the MODE key on the Rawson processor until the nominal rate
appears. The nominal rate should appear as follows for the different
modes of the Rawson processor.
“Sds/A=x,xxx,xxx” – Rawson plant mode
“Rate=xxxx.x Lb/A” – Rawson dry fertilizer mode
“Rate=xx.x Gal/A” – Rawson liquid fertilizer mode
Percent rate change: If the PF is not controlling the rate, ignore this
setting. If the PF is controlling the rate, this setting must equal the “Steps”
setting in the Rawson processor.
The “Steps” setting is not changeable or viewable in the Accu-Plant
processor. The settings are…
4.00% for plant mode of Accu-Plant processor
6.66% for fertilizer mode of Accu-Plant processor
The “Steps” setting is changeable in the Accu-Rate processor. Press the
MODE key on the Accu-Rate processor until “Steps x.x%” appears. The
default settings for each mode are below.
4.00% for plant mode of Accu-Rate processor
6.66% for fertilizer mode of Accu-Rate processor
Cal. number for act. rate: Use the formula below for the appropriate
mode to determine this setting.
Planting mode - Press MODE key on processor to view the “# of
seeds=xxx.x” and “No. of Rows=xx” setting.
# of seeds
5
x No. of rows x 10 = Cal. number for act. rate
Liquid fertilizer mode - Press MODE key on processor to view
“Pump Disp x.xxxx”, “RateSetting xx.x” and “Ratio=xx.xx:1”
setting.
Pump Disp x Rate Setting x 10000
Ratio
= Cal. number for act. rate