beautypg.com

Pf 3000, Ag leader technology – Ag Leader PF3000 Harvest & Application Operators Manual User Manual

Page 248

background image

System Wiring

PF 3000

Ag Leader Technology

April 2002

7-8

Checking Header
Sensor
Connections

To check the header sensor for electrical connection, use an ohmmeter and
check for the following resistance’s:

Check at:

Pins

Ohms

Cab Cable (rectangular 25 pin conn.)

11 + 18

100-200

Cab Cable (rectangular 25 pin conn.)

10 + 18

700-1000

Cab Cable (rectangular 25 pin conn.)

10 + 11

1000

Distribution Cable (large round 24 pin conn.)

10 + 16

100-200

Distribution Cable (large round 24 pin conn.)

9 + 16

700-1000

Distribution Cable (large round 24 pin conn.)

9 + 10

1000

Header Sensor Cable (rectangular 3 pin conn.)

A + B

100-200

Header Sensor Cable (rectangular 3 pin conn.)

B + C

700-1000

Header Sensor Cable (rectangular 3 pin conn.)

A + C

1000

* * *