Calibrating Grain Weight

PF3000

(Harvest Mode)

Ag Leader Technology

April 2002

3-16

Step

Action

8

Press the PERFORM CAL key to start the calibration. The monitor
will start calibrating and then it will stop and display “Fast
Calibration Complete”.

9

If the…

Then…

Maximum error is more
than +/- 15 %

Press the CANCEL key to stop the
calibration and view the calibration
loads again. Select the load with the
highest error over +/- 15 % and press
the CAL ON/OFF key to uncheck the
load and eliminate it as a calibration
load. Press the PERFORM CAL key
again to restart the calibration.

Maximum error is less than
+/- 15 %

Press the ACCEPT key.

NOTE: The calibration error is the percent difference between the
actual weight and the estimated weight. The maximum error is the
error of the calibration load that has the highest error.

Example:
Actual weight: 10,000 Lbs.
Estimated weight: 10,100 Lbs.
Error: + 1 %

10

After pressing the ACCEPT key in step 9, the monitor will do the
following:

If you have...

Then...

Four or more calibration
loads

The monitor will continue to calibrate
reducing the calibration errors. Press the
EXIT key to view the calibration loads
and the calibration errors.

Less than four calibration
loads

The monitor is finished calibrating and
will display the calibration loads and
their errors again.