Pf3000, Ag leader technology – Ag Leader PF3000 Harvest & Application Operators Manual User Manual
Page 233
PF3000
Troubleshooting
Ag Leader Technology
Harvest Mode
April 2002
6-11
Problem
Cause
Solution
Auger doesn’t come on
and moisture remains
constant.
The elevator mount
has lost power.
Inspect the power cable to ensure it is not cut or
damaged.
Check inline fuse. IMPORTANT: Never
replace a blown fuse with anything larger than
15 Amps.
Inspect battery connections. The wire with the
inline fuse should be connected to the positive
terminal.
Average and
Instantaneous Yield Do
Not Agree
The acre calibration
is not set to 100%
The instantaneous yield does not account for the
acre calibration number and thus can give a
different yield from the average yield if the Area
Cal number is much different from 100%. Press
MENU, CAL and AREA to display Area Cal. See
“Incorrect Acre Counting” in this section if the
number is not 100%.
Incorrect Grain Weight
(lbs)
Not calibrated for this
grain type
See “Calibrating Grain Weight” in Calibration
Section.
Incorrect actual
weight entered.
Press MENU, CAL, WEIGHT, and SHOW CAL
LOADS. Scroll through the calibration loads and
verify that you have entered the actual weight in
the correct load and ensure the actual weight is
correct.
Remove any loads for which you know the actual
weight is incorrect.
After actual weights are adjusted calibrate the
monitor again. See “Calibrating Grain Weight” in
Calibration Section.
Calibration numbers
C1 through C11 are
set incorrectly.
Press MENU, CAL and WEIGHT key. Press
SHOW CAL NUMBERS to display calibration
numbers C1 through C11. If any of the C2 through
C11 calibration numbers are set to zero, select that
C value and press EDIT key. Use up/down arrow
keys to set the values on the calibration sheet for
that grain type, then press ACCEPT key. Calibrate
the monitor for grain weight. The C numbers will
set automatically to their correct value.