Application Rate Mode

April 2002

2-47

Avg. Speed

Swath

Application Rate between

Scale Factor

0-25 mph

0-80 ft

0-10 units/ac

1.000

0-10 mph

0-80 ft

11-100 units/ac

1.000

11-15 mph

0-50 ft

11-100 units/ac

1.000

11-15 mph

51-80 ft

11-100 units/ac

0.100

16-25 mph

0-80 ft

11-100 units/ac

0.100

0-25 mph

0-80 ft

101-500 units/ac

0.100

0-10 mph

0-80 ft

501-1000 units/ac

0.100

11-15 mph

0-50 ft

501-1000 units/ac

0.100

11-15 mph

51-80 ft

501-1000 units/ac

0.010

16-25 mph

0-80 ft

501-1000 units/ac

0.010

0-25 mph

0-80 ft

1001+ units/ac

0.010

2.

If you have a 440, 450, or 460 ignore this step, otherwise press
CONTRLER SETTINGS key. Set the following:

Controller Channel: Set to channel of Raven to record or
control rate.

Controller Operating Mode: Set to liquid or granular,
whichever type the Raven console is controlling.

3.

Press EXIT key to return to screen with ADVANCED
SETTINGS key on bottom. Press the ADVANCED
SETTINGS key.

Target Rate Outside Field: This only pertains to using a
.tgt prescription file.

Set to ZERO if want rate outside field to be zero.

Set to USE LAST if want rate to be the last rate used at
the time the vehicle is detected outside the field. This is
useful when the vehicle is being falsely detected outside
of the field during the outside pass.

Set to TGT DEFAULT if want rate outside field to be the
default rate stored in the .tgt prescription file.

Controller Time Delay: Set to 3 seconds. This is delay of
controller to change application equipment to new rate + 2
seconds.