Problem

Cause

Solution

Elevator speed is zero or
erratic.
NOTE: Elevator
speed must be between
250 and 650 rpm or there
will zero flow in bu/hr
.
(cont)

Elevator speed sensor
is bad or monitor
cables have a bad
connection.

While harvesting, determine if the low-elevator-
shaft-speed alarm is on. This indicates low or
erratic elevator speed. If the alarm is on:

At elevator speed sensor cable, disconnect

monitor elevator speed cable. If the alarms is still
ON replace elevator speed sensor.

If the alarm goes OFF when cable is

disconnected, inspect and reconnect cable.
Inspect monitor cables for signs of pinching or
cutting.
Use a volt-ohm meter to check for shorts and
continuity in elevator speed cable, distribution
cable, and cab cable. Refer to Reference Section
for proper readings.

Ground speed and
elevator speed
extension cables have
been interchanged.

On the distribution cable, look at the labels on the
elevator speed and ground speed cables to ensure
they are connected correctly.

Incorrect Temperature
Reading

Temperature offset
had been set to a
large negative or
positive number.
NOTE: this setting
should be between –
15 to 15 T OFFSET.

Press MENU, DIAG and YEILD to display
temperature calibration number (Temperature
Offset). If this number is not between –15% to
+15% calibrate temperature and recheck moisture
calibration.

Incorrect Temperature
Reading (cont.).

Cable connections are
bad.

Disconnect cab, distribution and moisture sensor
cables and inspect pins for corrosion. Inspect the
cables for cuts or pinches. Reconnect cables and
check temperature again.

AREA OFF Always
Displayed
NOTE: The
AREA ON must be
displayed to count acres.

Area count switch is
in down position.

Area count switch must be up to make AREA ON
appear on the screen.

Stop height number is
set too high.

Press MENU, CAL, STOP HGT and ENTER
HEIGHT to display stop height setting. Adjust
stop height so that when the head is raised AREA
OFF appears on the screen. NOTE: Stop height
settings can be different for different grain types
.