Status bar – HP StorageWorks 2.140 Director Switch User Manual

Page 55

background image

Overview

53

Director Element Manager User Guide

Status Bar

The status bar is located along the bottom of the Element Manager window. (See

Figure 3

on page 26 or

Figure 4

on page 27.) Then status bar includes a symbol

that displays on the left side of the bar and messages that display in the panel to
the right of the symbol. The symbol indicates the current operating status of the
director, and the messages provide descriptions of menu options as you move the
mouse pointer over the options under the menu bar.

See

Table 2

for the meaning of these status symbols and of the corresponding alert

text that displays in the Status table at the top of the Hardware View in the main
panel.

If a gray square displays in the status bar (no Ethernet connection), a reason for
the status displays in the Status table at the top of the Hardware View. See

Director Status Table

” on page 63 for details. See

Table 2

for the meanings of

status symbols that display in Element Manager views.

Table 2: Operating status—status bar and director Status table

Symbol

Status

bar

Director Status table

text

Meaning

Green

Circle

Fully Operational

All components and installed ports

are operational; no failures.

Yellow

Triangle

Redundant Failure

A redundant component has failed,

such as a power supply, and the

backup component has taken over

operation.

Minor Failure

A failure occurred which has

decreased the director operational

ability. Normal switching

operations are not affected.
One or more Port cards failed, but

at least one Port card is still

operational.
A fan has failed or is not rotating

sufficiently.
One of two CTP cards failed.
One of two SBAR cards failed.